Our PET acoustic panels are tested by SGS, an independent testing laboratory accredited by CNAS and recognised under ILAC-MRA. The tests below were carried out on Jiadian's own 12mm polyester fiber (PET) acoustic panels. Every report number is listed, so you can verify each report yourself at check.sgsonline.com.cn.

Test results at a glance

PropertyTest standardResultSGS report no.Date
Fire rating (North America)ASTM E84-24Class A (FSI 15, SDI 25)SDFTS25004023R02_ENJul 21, 2025
Fire rating (Europe)EN 13501-1:2018B-s1,d0SDFTS25004023R01_ENJul 21, 2025
Sound absorptionISO 354:2003NRC 0.85, αw 0.90, Sound Absorption Class ACZIN2507000242CM01_ENJul 16, 2025
Indoor air quality (VOC)ISO 16000-9 / -6 / -3TVOC 19.6 µg/m³, formaldehyde not detectedCANIN26026108101Oct 12, 2026

Fire and acoustic tests: 12mm PET acoustic panel, about 2.40 kg/m². Results apply to the samples tested.

Is the PET acoustic panel fire rated?

Yes. Our 12mm PET acoustic panel has been tested to both the North American and the European fire standards.

ASTM E84: Class A

  • Flame Spread Index (FSI): 15

  • Smoke-Developed Index (SDI): 25

  • Specimen: 12mm panel, 2400 × 600mm, front surface exposed

Under NFPA 101 Life Safety Code and the International Building Code (Section 803), a Class A interior wall and ceiling finish needs a flame spread index of 0 to 25 and a smoke-developed index of 0 to 450. With FSI 15 and SDI 25, the panel meets Class A, the highest of the three classes.

SGS ASTM E84 test report for 12mm PET acoustic panel: flame spread index 15, smoke-developed index 25, Class A

EN 13501-1: B-s1,d0

Classified to EN 13501-1:2018, based on the EN 13823 (SBI) and EN ISO 11925-2 single-flame tests.

ParameterResult
FIGRA (0.2 MJ)25.2 W/s
Total heat release, THR 600s2.0 MJ
Lateral flame spread to specimen edgeNo
Smoke growth rate, SMOGRA6.3 m²/s²
Total smoke production, TSP 600s14.2 m²
Flaming droplets or particlesNo
Ignition of filter paper (EN ISO 11925-2)No

What B-s1,d0 means: B is a very limited contribution to fire, s1 is the lowest smoke production class, and d0 means no flaming droplets. The classification covers the panel mechanically fixed on an A1 or A2 substrate, without joints.

SGS EN 13501-1 classification report for 12mm PET acoustic panel: B-s1,d0

How well does it absorb sound?

The 12mm PET acoustic panel was tested in a reverberation room to ISO 354:2003, mounted with a 200mm air cavity behind the panel (type E-200 mounting).

Frequency (Hz)125250500100020004000
Absorption coefficient αs0.430.780.990.750.920.99
  • NRC 0.85

  • Weighted sound absorption coefficient αw 0.90

  • Sound Absorption Class A

Sound absorption depends on how the panel is installed. The air cavity behind the panel improves low-frequency absorption, so panels mounted directly on a wall will give lower values. See the 12mm PET acoustic panel page for more mounting data.

SGS ISO 354 sound absorption test report for 12mm PET acoustic panel: NRC 0.85

Is it safe for indoor air?

Our PET acoustic panel was tested for volatile organic compounds (VOC) in an environmental chamber, with reference to ISO 16000-9, ISO 16000-6 and ISO 16000-3, measured on the 7th day.

  • Total volatile organic compounds (TVOC): 19.6 µg/m³

  • Formaldehyde: not detected

  • Acetaldehyde, benzene, toluene, xylene and styrene: not detected

  • All of the more than 70 individual compounds tested were below the detection limit of 2.0 µg/m³

The panels are bonded by heat using low-melt fibers, with no glue. Learn more on our Sustainability page.

SGS VOC chamber test report for PET acoustic panel: TVOC 19.6 micrograms per cubic metre, formaldehyde not detected

Is the factory certified?

Changshu Jiadian New Material Technology Co., Ltd. holds three management system certificates for the production of polyester fiber sound-absorbing board, issued by Beijing EMIE-CYBER Inspection Certification Co., Ltd.:

CertificateRegistration no.Valid until
ISO 9001:2015 (quality)2792409Q60085R0SSep 9, 2027
ISO 14001:2015 (environment)2792407E60085R0SJul 23, 2027
ISO 45001:2018 (occupational health and safety)2792407S60085R0SJul 23, 2027

The certificates can be checked at cx.cnca.cn.

Jiadian ISO 9001, ISO 14001 and ISO 45001 management system certificates

FAQ

How can I verify an SGS test report?

Each SGS report has a report number and a QR code. Enter the report number at check.sgsonline.com.cn to check that the report is genuine.

Can I get the full test reports?

Yes. Contact us and we will send the full PDF reports for your project or tender.

What is the difference between NRC and αw?

NRC is the average sound absorption at 250, 500, 1000 and 2000 Hz. αw is a single weighted value calculated from the absorption curve, and it is used to give the sound absorption class (A to E). Both are calculated from the same ISO 354 measurement.

Need test reports for a project? Request the full reports or browse our PET acoustic panels.